Technisches Datenblatt
PVC Power Cable for Servo Motors 0.6/1 kV similar to Lenze u. Indramat standard
Application
These screened cables provide power to servos and motors for fixed or low dynamic two- dimensional movements from 1.5 to 50 mm² cross section
Construction
Power core
Stranded bare copper wires class 5 acc. IEC 60228
Insulation: TPM
Core identification:
- U/L1/C/L+
- V/L2
- W/L3/D/L– green/yellow
Signal pair
Stranded bare copper wires class 5 acc. IEC 60228
Insulation: TPM
Core identification: white black
2 cores stranded together with filler plastic tape
tinned copper braid plastic tape
Cable assembly with fillers Plastic tape
Tinned copper braid PVC jacket
Colour orange (RAL 2003)
Technical Data at +20 °C
DC conductor resistance:
power cores: acc. IEC 60228 class 5
signal cores: < 13.7 Ω/km
Insulation resistance: 500 MΩ x km
Voltage test:
power cores: 4 kV (AC) 5 min. core/core
core/screen
signal cores: 4 kV (AC) 1 min. core/core
core/screen
Approvals
• VDE-Reg. acc. UL758
• style page 10492 (insulation) style page 2570 (jacket
• CSA C22.2 No. 210.2